The product models include: FST-1, FST-2 and FST-Z.
n The FST-Z unit is an integrated reverse osmosis seawater desalination device that combines and optimizes both 1st and 2nd reverse osmosis desalination units; after treatment, fresh water with TDS not exceeding 150mg/L is obtained from seawater. The unit mainly consists of a seawater feed pump (booster pump), multi-media filter, precision filter, cartridge filter, primary high-pressure pump, 1st reverse osmosis membrane, 2nd high-pressure pump, 2nd reverse osmosis membrane, piping valves, operational parameter display and control instruments, electrical control cabinet, and cleaning tank, with all components installed on a common base frame.
|
Model Parameter |
FST-1 | FST-2 | FST-Z |
| Feed water |
Seawater TDS(ppm)≤45000mg/L |
1st RO System Production Water TDS(ppm)≤500mg/L |
Seawater TDS(ppm)≤45000mg/L |
| Feed pressure | 0-4bar, -2℃~40℃ | 0-4bar, 0℃~40℃ |
0-4bar, -2°C~40°C |
| Production water | TDS≤500mg/L | TDS≤150mg/L | TDS≤150mg/L |
| Production capacity |
20-240m³/day incorporates a 20% redundancy in water production capacity. |
15-180m³/day incorporates a 20% redundancy in water production capacity. |
15-300m³/day incorporates a 20% redundancy in water production capacity. |
| Gross weight (wet) | 1230-7500kg | 260-950kg | 1550-10500kg |
| Concentrated water discharge pressure | ≥3bar | ≥3bar | ≥3bar |
| Permeate water pressure | ≤3bar (back pressure) | ≤3bar (back pressure) | ≤3bar (back pressure) |
| Inlet and outlet connection | Provide paired flanges | Provide paired flanges | Provide paired flanges |
n Dual operation modes – Supports both automatic and manual control.
n One-touch start – Enables quick system activation with a single button.
n Overpressure protection for 1st high-pressure pump discharge – If discharge pressure exceeds the
set limit, the system shuts down automatically and triggers audible & visual alarms.
n Undervoltage protection for 1st high-pressure pump intake – If feedwater supply is insufficient (pressure below the set value), the system shuts down automatically and activates audible & visual alarms.
n Overpressure protection for 2nd high-pressure pump discharge – If discharge pressure exceeds the set limit, the device automatically bypasses and discharges the substandard water, and issues an alarm signal.
n High TDS alarm for 2nd product water – If the TDS (total dissolved solids) exceeds 150mg/L, the system automatically diverts non-compliant water to bypass discharge and issues an alarm.
n Rejection of substandard treated water – If the desalinated water conditioning/disinfection system fails to meet quality standards, the RO unit receives the alarm signal, switches to the reject water line, and discharges non-compliant product water. The touchscreen displays real-time alarm information.